Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 52
Filter
1.
Heart Vessels ; 2024 Mar 18.
Article in English | MEDLINE | ID: mdl-38494555

ABSTRACT

Epicardial adipose tissue (EAT) induces inflammation in the atria and is associated with atrial fibrillation (AF). Several studies have examined the relationship between EAT volume (EAT-V) and density (EAT-D) and the presence of AF after catheter ablation. However, conclusions have been inconsistent. This study included 43 consecutive patients who underwent catheter ablation for AF and 30 control patients. EAT-V and EAT-D around the entire heart, entire atrium, left atrium (LA), and right atrium (RA) were measured in detail using reconstructed three-dimensional (3D) EAT images from dual-source computed tomography (CT). None of the measurements of EAT-V differed significantly between patients with AF and controls or between patients with recurrent AF and those without. On the other hand, all measurements of EAT-D were higher in patients with AF than in controls (entire atrium, p < 0.001; RA, p < 0.001; LA, p = 0.002). All EAT-D measurements were associated with the presence of AF. Among patients with AF who underwent ablation, all EAT-D measurements were higher in patients with recurrent AF than in those without. The difference was significant for EATRA-D (p = 0.032). All atrial EAT-D values predicted recurrent AF (EATRA-D: hazard ratio [HR], 1.208; 95% confidence interval [95% CI], 1.053-1.387; p = 0.007; EATLA-D: HR, 1.108; 95% CI 1.001-1.225; p = 0.047; EATatrial-D: HR, 1.174; 95% CI 1.040-1.325; p = 0.010). The most sensitive cutoffs for predicting recurrent AF were highly accurate for EATRA-D (area under the curve [AUC], 0.76; p < 0.01) and EATatrial-D (AUC = 0.75, p < 0.05), while the cutoff for EATLA-D had low accuracy (AUC, 0.65; p = 0.209). For predicting the presence of AF and recurrent AF after catheter ablation, 3D analysis of atrial EAT-D, rather than EAT-V, is useful.

2.
Leg Med (Tokyo) ; 66: 102358, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38056179

ABSTRACT

Spinal cord injury is difficult to detect directly on postmortem computed tomography (PMCT) and it is usually diagnosed by indirect findings such as a hematoma in the spinal canal. However, we have encountered cases where the hematoma-like high-attenuation area in the cervical spinal canal was visible on PMCT, while no hematoma was observed at autopsy; we called it a "pseudo hematoma in the cervical spinal canal (pseudo-HCSC)." In this retrospective study, we performed statistical analysis to distinguish true from pseudo-HCSC. The cervical spinal canal was dissected in 35 autopsy cases with a hematoma-like high-attenuation area (CT values 60-100 Hounsfield Unit (HU)) in the spinal canal from the first to the fourth cervical vertebrae in axial slices of PMCT images. Of these 22 had a hematoma and 13 did not (pseudo-HCSC). The location and length of the hematoma-like high-attenuation and spinal cord areas were assessed on reconstructed PMCT images, true HCSC cases had longer the posterior hematoma-like area and shorter the spinal cord area in the midline of the spinal canal (P < 0.05). Furthermore, we found that true HCSC cases were more likely to have fractures and gases on PMCT while pseudo-HCSC cases were more likely to have significant facial congestion (P < 0.05). We suggest that pseudo-HCSC on PMCT is related to congestion of the internal vertebral venous plexus. This study raises awareness about the importance of distinguishing true HCSC from pseudo-HCSC in PMCT diagnosis, and it also presents methods for differentiation between these two groups.


Subject(s)
Hematoma , Postmortem Imaging , Humans , Retrospective Studies , Hematoma/diagnostic imaging , Neck , Spinal Canal/diagnostic imaging
3.
Front Cardiovasc Med ; 10: 1278603, 2023.
Article in English | MEDLINE | ID: mdl-37965084

ABSTRACT

Background: Symptomatic gastric hypomotility (SGH) is a rare but major complication of atrial fibrillation (AF) ablation, but data on this are scarce. Objective: We compared the clinical course of SGH occurring with different energy sources. Methods: This multicenter study retrospectively collected the characteristics and clinical outcomes of patients with SGH after AF ablation. Results: The data of 93 patients (67.0 ± 11.2 years, 68 men, 52 paroxysmal AF) with SGH after AF ablation were collected from 23 cardiovascular centers. Left atrial (LA) ablation sets included pulmonary vein isolation (PVI) alone, a PVI plus a roof-line, and an LA posterior wall isolation in 42 (45.2%), 11 (11.8%), and 40 (43.0%) patients, respectively. LA ablation was performed by radiofrequency ablation, cryoballoon ablation, or both in 38 (40.8%), 38 (40.8%), and 17 (18.3%) patients, respectively. SGH diagnoses were confirmed at 2 (1-4) days post-procedure, and 28 (30.1%) patients required re-hospitalizations. Fasting was required in 81 (92.0%) patients for 4 (2.5-5) days; the total hospitalization duration was 11 [7-19.8] days. After conservative treatment, symptoms disappeared in 22.3% of patients at 1 month, 48.9% at 2 months, 57.6% at 3 months, 84.6% at 6 months, and 89.7% at 12 months, however, one patient required surgery after radiofrequency ablation. Symptoms persisted for >1-year post-procedure in 7 patients. The outcomes were similar regardless of the energy source and LA lesion set. Conclusions: The clinical course of SGH was similar regardless of the energy source. The diagnosis was often delayed, and most recovered within 6 months, yet could persist for over 1 year in 10%.

4.
Pacing Clin Electrophysiol ; 46(12): 1526-1535, 2023 12.
Article in English | MEDLINE | ID: mdl-37899685

ABSTRACT

BACKGROUND: Preprocedural detection of the running course of the right pericardiophrenic bundles (PBs) is considered to be useful in preventing phrenic nerve (PN) injury during catheter ablation for atrial fibrillation (AF). However, previous studies using the arterial phase of contrast-enhanced computed tomography (CT) reported a relatively low right PBs detection rate. METHODS: This study included 63 patients with AF who underwent catheter ablation and preoperative contrast-enhanced CT imaging of the venous and arterial phases (66.7 ± 10.2 years; 44 male). The venous phase of contrast-enhanced CT significantly improved the detection rate of PBs compared to the arterial phase (96.8% vs. 60.3%, p < .001), and PBs were detected in the venous phase only in 23 (36.7%) patients. No significant differences were observed between the right PBs detection rate using non-contrast CT versus the arterial phase of contrast-enhanced CT (p = .37). Patients without visualization of the right PBs during the arterial phase had a higher frequency of chronic heart failure (p = .0083), lower left ventricular ejection fraction (p = .021), and a higher CHADS2 score (p = .048) than those with visualization. In five patients whose right PBs could only be detected during the venous phase of contrast-enhanced CT, the reconstructed running course of the right PBs corresponded with the PN generated by electrical high-output pacing. CONCLUSION: Contrast-enhanced CT images of the venous phase, rather than the arterial phase, are useful in detecting the right PBs, especially in patients with heart failure or reduced left ventricular ejection fraction.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Heart Failure , Pulmonary Veins , Humans , Male , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheter Ablation/methods , Heart Failure/surgery , Phrenic Nerve/diagnostic imaging , Phrenic Nerve/injuries , Pulmonary Veins/surgery , Stroke Volume , Tomography, X-Ray Computed/methods , Ventricular Function, Left , Female , Middle Aged , Aged
5.
Front Cardiovasc Med ; 10: 1161691, 2023.
Article in English | MEDLINE | ID: mdl-37576113

ABSTRACT

Background: Mechanisms underlying atrial fibrillation (AF) are widely complex and vary tremendously among individuals. Objectives: This retrospective study aimed to investigate the association between AF activation patterns and clinical outcomes post-ablation. Methods: Fifty-five AF patients (64.0 ± 12.9 years; 41 men; 17 paroxysmal) underwent bi-atrial endocardial driver mapping during AF pre-ablation with a real-time phase mapping system (ExTRa Mapping). The nonpassively activated ratio (%NP) of meandering rotors and multiple wavelets relative to the recording time was evaluated in 26 atrial segments [15 in the left atrium (LA) and 11 in the right atrium]. Irrespective of the mapping results, all patients underwent standard AF ablation via cryoballoons and/or radiofrequency catheters. Results: In a median follow-up interval of 27(14-30) months, 69.1% of patients were free from recurrent arrhythmias and antiarrhythmic drugs at one year post-procedure. Patients with recurrent AF were more likely to have non-paroxysmal AF, a significantly larger LA size, and higher LA maximal %NP(LAmax%NP) and LA anterior wall %NP(LAAW%NP) than those without recurrent AF. A multivariate Cox regression analysis showed that both an LAmax%NP (hazard ratio [HR] = 1.075; 95% confidence interval [CI] = 1.02-1.14, p = 0.012) and LAAW%NP (HR = 1.061; 95% CI = 1.01-1.11, p = 0.013) were independent predictors of atrial arrhythmia recurrence. The optimal cutoff points for the LAmax%NP and LAAW%NP for predicting AF recurrence were 64.5% and 60.0%, respectively. A Kaplan-Meier analysis demonstrated that both an LAmax%NP > 64.5% (p = 0.0062) and LAAW%NP > 60.0% (p = 0.014) were associated with more frequent AF recurrences. Conclusion: Baseline AF activation pattern mapping may aid in predicting freedom from arrhythmias after standard AF ablation procedures.

7.
Heart Vessels ; 38(7): 929-937, 2023 Jul.
Article in English | MEDLINE | ID: mdl-36823474

ABSTRACT

Successful atrial fibrillation (AF) ablation can improve reduced left ventricular ejection fraction (LVEF) with AF, which is defined as arrhythmia-induced cardiomyopathy (AIC). However, it is difficult to pre-procedurally predict the presence of AIC. We aimed to explore the pre-procedural predictors of AIC in patients with AF and reduced LVEF. This study included 60 patients with a reduced LVEF (LVEF < 50%; 69.1 ± 8.8 years; 45 men) who underwent successful AF ablation. Responders were defined as patients whose LVEF post-procedurally improved to the normal range (≥ 50%). Multivariate analysis revealed that the log-transformed pre-procedural troponin I (TnI) levels (odds ratio [OR] = 0.059; 95% confidence interval [CI] = 0.0052-0.42, p = 0.003) and age (OR = 0.91; 95% CI = 0.82-1.00, p = 0.044) were independent predictors of post-procedural LVEF recovery; further, low TnI levels (< 11.1 pg/ml) predicted LVEF recovery (sensitivity, 79.1%; specificity, 76.5%; positive predictive value, 89.5%; and negative predictive value, 59.1%). There were no significant differences in TnI levels between the baseline and 1 month after the procedure. However, four patients with high baseline TnI levels showed a > 50% reduction in the TnI levels post-procedurally, with three of these patients showing LVEF recovery. Low pre-procedural TnI levels can predict LVEF recovery after successful AF ablation in patients with reduced LVEF.


Subject(s)
Atrial Fibrillation , Cardiomyopathies , Ventricular Dysfunction, Left , Male , Humans , Atrial Fibrillation/complications , Atrial Fibrillation/diagnosis , Ventricular Function, Left , Troponin I , Stroke Volume , Ventricular Dysfunction, Left/diagnosis , Ventricular Dysfunction, Left/etiology , Cardiomyopathies/complications , Cardiomyopathies/diagnosis
8.
J Cardiovasc Electrophysiol ; 33(12): 2599-2605, 2022 12.
Article in English | MEDLINE | ID: mdl-36104930

ABSTRACT

BACKGROUND: Even a short duration of paroxysmal episodes of atrial fibrillation (AF) is associated with sinus node (SN) remodeling and a reduced SN reserve or dysfunction. The number of earliest atrial activation sites (EASs) during sinus rhythm decreases according to the decrease in the SN reserve. OBJECTIVE: We sought to evaluate the EASs during sinus rhythm using an ultrahigh-density mapping system. METHODS: This study included 35 patients (supraventricular tachycardia [SVT]/paroxysmal atrial fibrillation [PAF]/persistent atrial fibrillation [PsAF] = 5/21/9) who underwent ultrahigh-resolution endocardial mapping of the SN area at rest and during ß-stimulation. The number of EASs was determined by the Lumipoint™ algorithm. RESULTS: The number of EASs was greatest in SVT patients both at rest (SVT/PAF/PsAF = 1.4 ± 0.8/1.0 ± 0/1.0 ± 0, p = .04) and during ß-stimulation (SVT/PAF/PsAF = 2.6 ± 1.0/1.3 ± 0.6/1.0 ± 0, p < .01). The number significantly increased with ß-stimulation as compared to baseline in the PAF patients (p = .02), but not in the PsAF patients. The brain natriuretic peptide (BNP) level was significantly higher in AF than SVT patients (SVT/PAF/PsAF = 12.3 [10.1-14.5]/25.7 [14.8-36.0]/73.4 [57.6-140] pg/ml, p < .01). In the PAF patients, the BNP level was significantly higher in those with unicentric EASs than multicentric EASs during ß-stimulation (28.1 [19.1-46.5] vs. 13.1 [9.4-26.9] pg/ml, p = .03), and the optimal cutoff point for the BNP level predicting unicentric EASs was 21.8 pg/ml (sensitivity 82.6%; specificity 85.7%). CONCLUSIONS: AF patients have a smaller number of EASs and poorer response to ß-stimulation than non-AF patients. An elevated BNP level might predict subclinical SN dysfunction in patients with PAF.


Subject(s)
Atrial Fibrillation , Tachycardia, Paroxysmal , Tachycardia, Supraventricular , Humans , Atrial Fibrillation/diagnosis , Sick Sinus Syndrome , Heart Atria , Sinoatrial Node
9.
Forensic Sci Int ; 339: 111419, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35994987

ABSTRACT

Respiratory viruses can cause fatal systemic infections; therefore, post-mortem diagnosis is essential in forensic autopsy cases. However, little is known regarding the distribution of respiratory viruses in the body. In this study, we investigated the anatomical distribution of respiratory viruses in 48 forensic autopsy cases suspected of viral infections at our institute. Fast Track Diagnostics (FTD) Respiratory Pathogens 21 was used as a screening test for 20 respiratory viruses in nasopharyngeal swabs. In cases with positive results for virus detection by the screening test, the detected viruses were quantified in body fluid and organ specimens by virus-specific real-time reverse transcription polymerase chain reaction (RT-PCR) and digital PCR. Viruses were detected in 33 cases, with the viral distribution and load differing among the cases. Since various respiratory viruses were detected from the nasopharyngeal swab and its viral load was higher than those of other body fluid specimens, the nasopharyngeal swab was suggested as a useful specimen for the post-mortem detection of respiratory viruses. Viruses were detected in almost all specimens including the serum in six cases. Considering the viral distribution in the body, pathological findings, and ante-mortem symptoms, these cases were presumed to be systemically infected, having died in the acute infection phase. In conclusion, the anatomical distribution of respiratory viruses can help indicate ante-mortem systemic conditions and the cause of death.


Subject(s)
Respiratory Tract Infections , Virus Diseases , Viruses , Autopsy , Humans , Real-Time Polymerase Chain Reaction , Respiratory Tract Infections/diagnosis , Virus Diseases/diagnosis , Viruses/genetics
10.
Heart Vessels ; 37(12): 2049-2058, 2022 Dec.
Article in English | MEDLINE | ID: mdl-35790552

ABSTRACT

BACKGROUND: Few studies have examined whether catheter ablation for AF patients improves biomarkers other than serum levels of brain natriuretic peptide (BNP) and renal function. This study was to explore whether catheter ablation for atrial fibrillation (AF) patients affects uric acid (UA), glucose and lipid metabolism. METHODS AND RESULTS: A total of 206 patients (66.6 ± 10.4 years; 132 men) who underwent initial AF ablation without changes to oral medications were included. Baseline BNP and UA levels significantly decreased at 1 year after ablation (p < 0.05 each). Changes in UA level correlated significantly with pre-procedural UA level (r = 0.57). In multivariable logistic regression modeling, pre-procedural UA level, persistent AF, and hemoglobin A1c (p < 0.05 each) were independent predictors of post-procedural UA level decline. Significant improvements in both persistent and paroxysmal AF patients were identified, and the magnitude of post-procedural serum UA level decline after ablation (ΔUA) was significantly greater in patients with persistent AF (0.8 ± 1.0 mg/dl) than in those with paroxysmal AF (0.2 ± 0.8 mg/dl, p < 0.001). Of the 48 patients with high UA level before procedure, 28 patients showed improvement in UA level to normal range. CONCLUSIONS: Catheter ablation for AF patients significantly improved serum UA levels without obvious influences of heart failure, renal function, or inflammation, suggesting that AF ablation may be effective for AF patients with hyperuricemia. Trial registration The study was approved by the Research Ethics Committee of University of Fukui (no. 20210132) and clinical trial registration (UMIN000044669).


Subject(s)
Atrial Fibrillation , Catheter Ablation , Uric Acid , Aged , Female , Humans , Male , Middle Aged , Atrial Fibrillation/surgery , Biomarkers/blood , Glucose/metabolism , Lipids/blood , Treatment Outcome , Uric Acid/blood
11.
J Interv Card Electrophysiol ; 65(1): 123-131, 2022 Oct.
Article in English | MEDLINE | ID: mdl-35488961

ABSTRACT

BACKGROUND: An acute cryothermal ablation lesion contains both reversible and irreversible elements. However, differences in lesions created with cryoballoon pulmonary vein isolation (PVI) between the acute and chronic phases have not been fully elucidated. METHODS: We retrospectively analyzed 23 consecutive patients with atrial fibrillation who underwent cryoballoon PVI during the initial procedure followed by a second ablation procedure. In all patients, cryoballoon PVI lesions were evaluated with high-resolution voltage mapping just after PVI (acute phase) and during the second session (chronic phase). We compared the area and width of the non-isolated left atrial posterior wall (NI-LAPW) with voltage ≥ 0.5 mV during both sessions. RESULTS: PVI was successfully achieved in all patients. Cryoballoon PVI lesions were re-evaluated at 11 [2-17] months post-procedure. During the chronic phase, NI-LAPW width became significantly larger at the level of the roof (change, 5.8 ± 5.5 mm; p < 0.001) and at the level of the carina (change, 3.3 ± 7.0 mm; p < 0.05), and NI-LAPW area became significantly larger (change, 1.5 ± 1.9 cm2; p < 0.001) compared with the acute phase. Eight patients without any PV reconnections also had larger NI-LAPW areas (change, 1.3 ± 1.2 cm2; p < 0.05) during the chronic phase. Conduction resumption confined to the right carina was observed in 1 (4.3%) patient who presented with circumferential PVI that included the carina during the first session. CONCLUSION: Acute cryoballoon PVI lesions significantly regressed during the chronic phase. PV reconnections and the isolation area should be carefully re-evaluated during the second procedure.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheter Ablation/methods , Cryosurgery/methods , Humans , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Recurrence , Retrospective Studies , Treatment Outcome
12.
Heart Vessels ; 37(8): 1425-1435, 2022 Aug.
Article in English | MEDLINE | ID: mdl-35174414

ABSTRACT

Interatrial conduction consists of various muscular bundles, including the Bachmann bundle. In this study, we investigated interatrial activation patterns using ultrahigh-resolution left atrial endocardial mapping. This study investigated 58 patients who underwent catheter ablation of atrial arrhythmia via an ultrahigh-resolution mapping system (Rhythmia) at our hospital from May 2020 to January 2021. Left atrial voltage maps and activation maps were acquired after the ablation procedure during right atrial appendage (RAA) pacing. We defined left atrial breakout sites (LABSs) as centrifugal activation patterns shown by the LUMIPOINT Activation Search Tool. The distance between each LABS in the left atrial anterior wall and the superior border of the interatrial septum (DLABS-IAS) was measured on the shell of the electroanatomical map, and anterior LABSs were divided equally into roof- and septal-side groups. Fifty-three (91%) patients underwent cryoballoon pulmonary vein isolation. Ultrahigh-resolution left atrial mapping was successfully performed in all patients (6831 ± 2158 points). A total of 82 LABSs were identified in left atrial anterior wall; 34 patients had single LABS and 24 patients had dual LABSs. The mean DLABS-IAS was 10.3 ± 9.6 mm. Seven patients also exhibited posterior LABS near the interatrial raphe below the right inferior pulmonary vein. Patients with a single roof-side LABS had significantly shorter left atrial activation times than those with a single septal-side LABS (81.6 ± 13.2 ms vs. 93.5 ± 13.7 ms, p < 0.05). Interatrial conduction patterns during RAA pacing varied between patients and affected the left atrial activation time.


Subject(s)
Atrial Appendage , Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Atrial Appendage/diagnostic imaging , Atrial Appendage/surgery , Atrial Fibrillation/diagnosis , Atrial Fibrillation/surgery , Cardiac Pacing, Artificial/methods , Catheter Ablation/adverse effects , Heart Atria/diagnostic imaging , Heart Atria/surgery , Humans , Pulmonary Veins/surgery
13.
BMC Cardiovasc Disord ; 22(1): 57, 2022 02 16.
Article in English | MEDLINE | ID: mdl-35172730

ABSTRACT

BACKGROUND: Left atrial roof-dependent tachycardias (LARTs) are common macroreentrant atrial tachycardias (ATs). We sought to characterize clinical LARTs using an ultra-high resolution mapping system. METHODS: This study included 22 consecutive LARTs in 21 patients who underwent AT mapping/ablation using Rhythmia systems. RESULTS: Three, 13, 4, and 2 LART patients were cardiac intervention naïve (Group-A), post-roof line ablation (Group-B), post-atrial fibrillation ablation without linear ablation (Group-C), and post-cardiac surgery (Group-D), respectively. The mean AT cycle length was 244 ± 43 ms. Coronary sinus activation was proximal-to-distal or distal-to-proximal in 16 (72.7%) ATs. The activation map revealed 13 (59.1%) clockwise and 9 (40.9%) counter-clockwise LARTs. A 12-lead synchronous isoelectric interval was observed in 10/19 (52.6%) LARTs. The slow conduction area was identified on the LA roof, anterior/septal wall, and posterior wall in 18, 6, and 2 ATs, respectively. Twenty concomitant ATs among 13 procedures were also eliminated, and peri-mitral AT coexisted in 7 of 9 non-group-B patients. In group-B, the conduction gap was predominantly located on the mid-roof. Sustained LARTs were terminated by a single application and linear ablation in 6 (27.3%) and 9 (40.9%), while converting to other ATs in 7 (31.8%) LARTs. Complete linear block was created without any complications in all, however, ablation at the mid-posterior wall was required to achieve block in 4 (18.2%) procedures. During 14.0 (6.5-28.5) months of follow-up, 17 (81.0%) and 19 (90.5%) patients were free from any atrial tachyarrhythmias after single and last procedures. CONCLUSIONS: The LART mechanisms were distinct in individual patients, and elimination of all concomitant ATs was required for the management.


Subject(s)
Action Potentials , Catheter Ablation , Electrophysiologic Techniques, Cardiac/instrumentation , Heart Atria/surgery , Tachycardia, Supraventricular/surgery , Aged , Aged, 80 and over , Catheter Ablation/adverse effects , Female , Heart Atria/physiopathology , Heart Rate , Humans , Male , Middle Aged , Predictive Value of Tests , Recurrence , Tachycardia, Supraventricular/diagnosis , Tachycardia, Supraventricular/physiopathology , Time Factors , Treatment Outcome
14.
Heart Vessels ; 37(7): 1203-1212, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35064297

ABSTRACT

The electrophysiological properties of the gap associated with the cavotricuspid isthmus (CTI) block line near the inferior vena cava (IVC) are not fully elucidated. Of 143 patients who underwent CTI block line ablation between September 2020 and April 2021, high-resolution CTI gap mapping was performed for 15 patients. Four patients were identified as having a gap near the IVC (IVC-side gap) despite wide double potentials (DPs) with > 90 ms intervals at the block line. Detailed gap mapping during coronary sinus ostial pacing was performed before and after touch-up ablation. CTI conduction delays caused by an IVC-side gap were classified into 3 patterns: (1) conduction delay at the IVC-side gap without detouring gap conduction, (2) detouring gap conduction due to intrinsic lower lateral right atrium (LLRA)-IVC functional block, and (3) detouring gap conduction due to LLRA-IVC conduction block created by lateral deviation of the CTI ablation line. In Pattern 2, IVC-side gap conduction traveled backward toward the crista terminalis below the LLRA-IVC junction and came back forward again above the border. One patient presented with a head-to-bottom activation pattern of the lateral right atrium (pseudo-CTI block). Pattern 3 was caused by lateral deviation of initial RF deliveries and presented with the same course as intrinsic LLRA-IVC functional block. All patients had wide DP intervals near the tricuspid annulus (mean, 112 ms) and just above the gap site (mean, 109 ms). An IVC-side gap associated with the CTI block line can present with various conduction delay patterns.


Subject(s)
Atrial Flutter , Catheter Ablation , Atrial Flutter/diagnosis , Atrial Flutter/surgery , Heart Atria/surgery , Heart Block/diagnosis , Heart Block/etiology , Humans , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Vena Cava, Inferior/surgery
15.
J Interv Card Electrophysiol ; 63(1): 143-152, 2022 Jan.
Article in English | MEDLINE | ID: mdl-33575920

ABSTRACT

BACKGROUND: The novel fourth-generation cryoballoon (4th-CB) is characterized by a shorter-tip that potentially facilitates better time-to-isolation (TTI) monitoring. We sought to clarify the advantages and disadvantages of the 4th-CB compared to the second-generation cryoballoon (2nd-CB) in pulmonary vein isolation (PVI). METHODS: Forty-one and 49 consecutive atrial fibrillation patients underwent 2nd-CB and 4th-CB PVIs using 28-mm balloons and short freeze strategies. When effective freezing was not obtained, the CB was switched to the other CB. RESULTS: The rate of successful PVIs was significantly higher for 2nd-CBs than 4th-CBs (162/162[100%] vs. 178/193[92.2%] PVs, p < 0.0001). The difference was significant for lower PVs, especially right inferior PVs (RIPVs)(p = 0.005). In a total of 15 PVs in 11 patients, 4th-CBs were switched to 2nd-CBs, and 14/15(93.3%) PVs were successfully isolated. The balloon temperature tended to reach -55℃ more frequently with 2nd-CBs than 4th-CBs during RIPV ablations (15/41[36.6%] vs. 12/49[24.5%], p = 0.21). The TTI monitoring capability was significantly higher with 4th-CBs than 2nd-CBs (131/188[69.7%] vs. 83/160[51.9%] PVs, p = 0.0007). The difference was significant for right superior and left inferior PVs, but not for left superior PVs. Even if PVs requiring crossover were excluded, the total freeze duration (715±152 vs. 755±215 seconds, p = 0.31) tended to be shorter for 2nd-CBs than 4th-CBs. The incidence of phrenic nerve injury was similar for 2nd-CB and 4th-CB ablation (0/41 vs. 2/49, p = 0.12) CONCLUSIONS: The 4th-CB's shorter balloon tip enabled a significantly higher capability of TTI monitoring; however, it resulted in significantly lower rates of successful PVIs than the 2nd-CB, especially for the RIPVs.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Freezing , Humans , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Treatment Outcome
16.
Pacing Clin Electrophysiol ; 45(5): 589-597, 2022 05.
Article in English | MEDLINE | ID: mdl-34427933

ABSTRACT

BACKGROUND: Additional benefit of cryoballoon left atrial roof line ablation (CB-RA) beyond cryoballoon pulmonary vein isolation (CB-PVI) is suggested in patients with persistent atrial fibrillation (PsAF). We sought to investigate the feasibility of CB-RA for PsAF and to determine the ablation area. METHODS AND RESULTS: Fifty-three PsAF patients (67[58.5-75.5] years, 36 men, 11 longstanding PsAF) underwent CB-PVI. Subsequently, 44(83.0%) out of 53 patients underwent additional CB-RA. Voltage maps were created in all patients with a high-resolution mapping system. The total number and duration of CB-RAs were 3.9 ± 0.7 and 468 ± 84 s. LA roof areas were complete low voltage areas (LVAs) /scar in 37/44(84.1%) patients ("complete roof modification"). The normal LA posterior wall (LAPW) voltage area was 6.1(4.1-8.4) cm2 , and the %LAPW isolation area was 61.0(47.2-71.7)%. The %LAPW isolation area was significantly greater in CB-RA patients than those without (64.0[54.2-73.2] vs. 45.0[39.5-50.5]%, p = .041) despite significantly larger LAs in the former group. The %LAPW isolation area was significantly greater in patients with transverse LA diameters < 45 mm than those ≥ 45 mm (p < .0001). The single procedure 1-year AF freedom was 87.4% (22.5% on antiarrhythmic drug) and tended to be higher in CB-RA patients than those without. Among the 44 CB-RA patients, it was significantly higher in patients with a complete roof modification than those without (94.4% vs. 75.0%, p = .0049). One CB-RA patient experienced a delayed cardiac tamponade requiring drainage at 4-months post-procedure. CONCLUSIONS: CB-RA significantly expanded the LAPW isolation area, and a complete roof modification resulted in a high arrhythmia freedom in PsAF patients.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Catheter Ablation/methods , Cryosurgery/methods , Humans , Male , Pulmonary Veins/surgery , Recurrence , Treatment Outcome
17.
J Cardiovasc Electrophysiol ; 33(1): 40-45, 2022 01.
Article in English | MEDLINE | ID: mdl-34676946

ABSTRACT

BACKGROUND: Cavo-tricuspid isthmus (CTI) linear ablation is performed not only for atrial flutter (AFL) but empirically during atrial fibrillation (AF) ablation in real-world practice.  PURPOSE: We sought to evaluate the safety and durability of the CTI ablation.  METHODS: This retrospective study included 1078 consecutive patients who underwent a CTI ablation. AFL was documented before or during the procedure in 249 (23.1%) patients, and an empirical CTI and AF ablation were performed in 829 (76.9%) patients.  RESULTS: CTI block was successfully created in 1051 (97.5%) patients with a 10.3 ± 6.6 min total radiofrequency time. Repeat procedures were performed for recurrent arrhythmias in 187 (17.3%) patients at a median of 11.0 (5.0-30.0) months postprocedure, and conduction resumption was identified in 68/174 (39.1%). Among those undergoing a CTI ablation with an AF ablation, the durability was significantly higher in those with than without documented AFL (78.1% vs. 58.2%, p = .031).  The total radiofrequency time was significantly shorter (9.0 ± 5.3 vs. 10.0 ± 6.4 [mins], p = .024) and durability significantly higher (78.1 vs. 58.7[%], p = .043) in the large-tip than irrigated-tip catheter group. Iatrogenic AFL was observed after the empiric CTI ablation in 11 (1.3%) patients. Procedure-related complications occurred in 15 (1.4%) patients. Eight patients experienced coronary artery spasms, including one with ventricular fibrillation following ST elevation on the ward. The other six patients experienced transient atrioventricular block and one experienced cardiac tamponade requiring drainage.  CONCLUSIONS: Despite a high acute CTI ablation success, the conduction block durability was relatively low after the empiric ablation. An empiric CTI ablation at the time of the AF ablation is not recommended.


Subject(s)
Atrial Fibrillation , Atrial Flutter , Catheter Ablation , Atrial Fibrillation/diagnosis , Atrial Fibrillation/etiology , Atrial Fibrillation/surgery , Atrial Flutter/diagnosis , Atrial Flutter/etiology , Atrial Flutter/surgery , Catheter Ablation/adverse effects , Catheter Ablation/methods , Humans , Retrospective Studies , Treatment Outcome
18.
J Interv Card Electrophysiol ; 64(3): 581-586, 2022 Sep.
Article in English | MEDLINE | ID: mdl-34292463

ABSTRACT

BACKGROUND: The time-to-isolation (TTI) may be a physiological predictor of durable isolations, and TTI-guided dosing strategies are widely performed in cryoballoon ablation. We sought to investigate the impact of the order of targeting the pulmonary veins (PVs) on the TTI values of left ipsilateral PVs. METHODS: This study included 144 atrial fibrillation patients who underwent PV isolations using 28-mm fourth-generation cryoballoons. In 101 patients, the left superior PV (LSPV) was targeted and followed by the left inferior PV (LIPV) (group 1), and the LIPV was targeted and followed by the LSPV in the remaining 43 (group 2). RESULTS: The total LSPV and LIPV freeze durations were 193 ± 60 and 171 ± 40 s, respectively. Real-time PV isolation monitoring was capable in 137 (95.1%) LSPVs and 119 (82.6%) LIPVs and in 112 (77.8%) patients (78 in group 1 and 34 in group 2) in both LSPVs and LIPVs. Among them, the LSPV TTI was significantly longer in group 1 than that in group 2 (54.8 ± 32.1 vs. 34.1 ± 17.3 s, p < 0.0001), while the LIPV TTI was significantly shorter in group 1 than that in group 2 (23.7 ± 11.8 vs. 39.2 ± 19.4 s, p < 0.0001). The ΔTTI ((TTI in LSPV)-(TTI in LIPV)) was significantly greater in group 1 than that in group 2 (31.1 ± 31.4 vs. - 5.0 ± 25.9 s, p < 0.0001). In 5 patients (3 in group 1 and 2 in group 2), initially targeted left PVs were not isolated despite complete vein occlusions, while they were by subsequent applications at the other ipsilateral PVs. CONCLUSIONS: In CB ablation, the order of targeting PVs highly influenced the TTI of the left PVs owing to the presence of electrical connections between left ipsilateral PVs.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Cryosurgery , Pulmonary Veins , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Freezing , Humans , Pulmonary Veins/diagnostic imaging , Pulmonary Veins/surgery , Treatment Outcome
19.
J Interv Card Electrophysiol ; 63(2): 333-339, 2022 Mar.
Article in English | MEDLINE | ID: mdl-33963960

ABSTRACT

PURPOSE: We aimed to elucidate the right atrial posterior wall (RAPW) and interatrial septum (IAS) conduction pattern during reverse typical atrial flutter (clockwise AFL: CW-AFL). METHODS: This study included 30 patients who underwent catheter ablation of CW-AFL (n = 11) and counter-clockwise AFL (CCW-AFL; n = 19) using an ultra-high resolution mapping system. RAPW transverse conduction block was evaluated by the conduction pattern on propagation maps and double potentials separated by an isoelectric line. The degree of blockade was evaluated by the %blockade, which was calculated by the length of the blocked area divided by the RAPW length. IAS activation patterns were also investigated dependent on the propagation map. RESULTS: The average %blockade of the RAPW was significantly smaller in patients with CW-AFL than those with CCW-AFL (25 [3-74]% vs. 67 [57-75]%, p < 0.05). CW-AFL patients exhibited 3 different RAPW conduction patterns: (1) a complete blockade pattern (3 patients), (2) moderate (> 25% blockade) blockade pattern (2 patients), and (3) little (< 25% blockade) blockade pattern (6 patients). In contrast, the little blockade pattern was not observed in CCW-AFL patients. Of 11 CW-AFL patients, 4, including all patients with an RAPW complete blockade pattern, had an IAS activation from the wavefront from the anterior tricuspid annulus (TA), and 6 had an IAS activation from the wavefronts from both the anterior TA and RAPW. One patient had IAS activation dominantly from the wavefront from the RAPW. CONCLUSIONS: RAPW transverse conduction blockade during CW-AFL was less frequent than during CCW-AFL, which possibly caused various IAS activation patterns.


Subject(s)
Atrial Flutter , Catheter Ablation , Arrhythmias, Cardiac/surgery , Atrial Flutter/diagnostic imaging , Atrial Flutter/etiology , Atrial Flutter/surgery , Catheter Ablation/adverse effects , Heart Atria/surgery , Heart Block , Humans
20.
J Interv Card Electrophysiol ; 64(2): 291-300, 2022 Aug.
Article in English | MEDLINE | ID: mdl-33755817

ABSTRACT

BACKGROUND: A novel technology able to measure the local impedance (LI) during radiofrequency ablation has become available for clinical use. We investigated the change in the LI characteristics during superior vena cava isolations (SVCIs) using a novel catheter equipped with mini-electrodes. METHODS: Twenty paroxysmal atrial fibrillation patients (68 ± 9 years; 14 males) underwent an SVCI by targeting breakthroughs. Subsequently, dormant conduction provoked by adenosine triphosphate (ATP) was evaluated. RESULTS: Electrical SVCIs were successfully achieved in all with 7.2 ± 3.0 radiofrequency applications (RFA) without any complications. The procedure and fluoroscopic times were 13.1 ± 8.1 and 2.8 ± 2.3 min. No ablation was required at the anteroseptal SVC in 19 (95.0%) patients. The baseline LI and generator impedance (GI) were 125 ± 23 and 105 ± 14Ω. LI drops during RFA were significantly greater than GI drops (17 ± 12 vs. 4 ± 4Ω, p < 0.001). The correlation between the LI drops and GI drops was relatively high (R = 0.69, p < 0.001). LI drops were highest at the septal SVC and lowest at the lateral followed by antero-lateral SVC. The baseline electrogram amplitude between the mini-electrodes and tip-ring electrodes was 1.2 ± 1.4 and 0.8 ± 0.6 mV. The mini-electrode amplitude is more sharply attenuated with a greater magnitude than the tip-ring amplitude (p < 0.001). ATP-provoked dormant conduction was exposed in 10/17 (58.8%) patients and antero-lateral SVC gap locations in 7. Antero-lateral SVC LI drops were similar between patients with and without dormancy. CONCLUSIONS: The LI drop magnitude during RFA significantly differed among the SVC segments. Antero-lateral SVC ATP-provoked dormant conduction was often exposed, and additional applications are recommended following the isolation for a robust SVCI.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Adenosine Triphosphate , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/surgery , Catheters , Electric Impedance , Humans , Male , Pulmonary Veins/surgery , Treatment Outcome , Vena Cava, Superior/diagnostic imaging , Vena Cava, Superior/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...